Room area and fixture check
Use this as a first-pass room check. Every reference figure is editable, and the result is written so a manager can take the assumptions and the shortfalls into an audit conversation.
-
01 Measure
Enter the room and floor facts
Use width and length, or enter a direct area. Add the people in the room, ceiling height, ventilation opening and the floor's sanitary fixture counts.
-
02 Set
Make the reference figures yours
The square-metre, fixture-ratio and ventilation figures are editable reference inputs. Check them against current local regulation and the customer's social-audit standard.
-
03 Print
Carry the shortfalls into the response
The page shows each criterion, maximum occupancy and fixture shortfalls before JavaScript runs. Print the result when the measured figures are ready.
Room area and fixture check
Room area and fixture check
These editable figures are a starting point only. Check current local regulation and the customer's social-audit standard before using this in an audit response.
- Floor area per person
- Pass
- Ventilation opening
- Fail
- Toilets
- Fail
- Showers
- Pass
- Washbasins
- Fail
- Maximum people this room supports
- 10
- Measured area per person
- 3
- Toilets short
- 1
- Showers short
- 0
- Washbasins short
- 1
This room provides 3 m² per person and supports 10 people at the editable reference figures; it is outside the reference figures, with 2 fixture places short.
Ceiling height: 2.5 metres
Questions to check
Treat this as a measured starting point, then confirm the current figures that apply to the building and customer.
Can I treat the figures as settled requirements?
No. They are editable reference figures for a first pass. Check current local regulation and the customer's social-audit standard before relying on the result.
How is maximum occupancy calculated?
The room area is divided by the editable floor-area reference figure and rounded down to a whole person. Fixture and ventilation results can still make the overall check fail.
What does a fixture shortfall mean?
It is the number of additional toilets, showers or washbasins needed to meet the editable reference ratio for the people on the floor. It is a planning prompt, not a legal conclusion.
Can I enter area directly?
Yes. A direct area overrides width multiplied by length when it is greater than zero. Leave it at zero to use the two measured dimensions.
Why is ceiling height shown separately?
Ceiling height is useful context for an audit response, but this tool does not attach a threshold to it. Confirm any applicable local or customer figure separately.
Does this store room measurements?
No. The check runs in this browser only, makes no network request and writes nothing to storage.